150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Collectively Screened Unarmoured Flame Retardant Instrumentation & Control Cables
Application
These elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in instrumentation, lighting and control circuits.
Standards
BS 6883
IEC 60332-3A Flame retardant
IEC 60754-1; IEC 60754-2 Corrosivity
IEC 61034-2 Smoke density
Cold bend and impact (-40°C) (on request)
CSA C22.2 No. 38-95 (on request)
Construction
Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.
Insulation: HF-EPR GP4 according to BS 7655 1.2.
Lay-up: Pairs, triples.
Collective Screen: Aluminium/polyester tape + drain wire tinned copper.
Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6
Mechanical and Thermal Properties
Minimum Internal Bending Radius: 8×OD
Temperature Range: -40℃ ~ +90℃
Dimensions and Weight
Construction No. of cores×Cross section |
Nominal Insulation Thickness | Nominal Sheath Thickness | Minimum Overall Diameter | Maximum Overall Diameter | Approx. Weight |
(mm²) | mm | mm | mm | mm | kg/km |
Multipair | |||||
3×2×0.75 | 0.8 | 1.2 | 12.6 | 14.5 | 175 |
7×2×0.75 | 0.8 | 1.4 | 16.6 | 18.7 | 330 |
12×2×0.75 | 0.8 | 1.6 | 21.7 | 24.2 | 530 |
20×2×0.75 | 0.8 | 1.8 | 27.3 | 30.1 | 830 |
27×2×0.75 | 0.8 | 1.9 | 31.1 | 34.2 | 1070 |
37×2×0.75 | 0.8 | 2.1 | 34.4 | 37.7 | 1430 |
3×2×1 | 0.8 | 1.2 | 13.3 | 15.3 | 185 |
7×2×1 | 0.8 | 1.4 | 17.6 | 19.8 | 360 |
12×2×1 | 0.8 | 1.6 | 23.1 | 25.7 | 590 |
20×2×1 | 0.8 | 1.8 | 29.1 | 31.9 | 920 |
27×2×1 | 0.8 | 2 | 33.3 | 36.6 | 1220 |
37×2×1 | 0.8 | 2.2 | 36.9 | 40.3 | 1630 |
Multitriple | |||||
3×3×0.75 | 0.8 | 1.3 | 14.2 | 16.2 | 230 |
7×3×0.75 | 0.8 | 1.4 | 19.4 | 21.9 | 440 |
12×3×0.75 | 0.8 | 1.7 | 24.2 | 26.8 | 730 |
3×3×1 | 0.8 | 1.3 | 15.1 | 17.1 | 260 |
7×3×1 | 0.8 | 1.5 | 20.9 | 23.4 | 510 |
12×3×1 | 0.8 | 1.7 | 25.8 | 28.5 | 840 |